Why choose lead4pass? Lead4pass offers latest Cisco CCNP Data Center 642-999 dumps exam questions and answers download to have a free try. The best useful Cisco CCNP Data Center 642-999 dumps pdf practice files and vce youtube demo update free shared. “Implementing Cisco Data Center Unified Computing” is the name of Cisco CCNP Data Center https://www.lead4pass.com/642-999.html exam dumps which covers all the knowledge points of the real Cisco exam. Newest helpful Cisco CCNP Data Center 642-999 dumps pdf training materials and study guides free update, pass Cisco 642-999 exam test quickly and easily at first attempt.

Download free latest Cisco 642-999 dumps pdf practice files: https://drive.google.com/open?id=1XCHpmRKo9HG6hXJraxo6SUOE0440YYem

Download free latest Cisco 642-997 dumps pdf practice files: https://drive.google.com/open?id=16rMmMcN0e3Z8WOpyhSL5Ai3YDxyo1z1j
642-999 dumps
QUESTION 1
When you create a vHBA, what will you achieve by enabling persistent binding?
A. This feature allows the binding of the SCSI targets to the vHBA, even across reboots.
B. This feature allows the binding of the same WWPN from the pool to the vHBA, even across reboots.
C. This feature allows the binding of the same WWNN from the pool to the vHBA, even across reboots.
D. This feature allows the binding of the Fibre Channel uplink to the vHBA, even across reboots.
Correct Answer: A

QUESTION 2
Which two tasks enable jumbo frames on a Cisco UCS system? (Choose two.)
A. In the LAN cloud on Cisco UCS Manager, configure MTU 9000 in the uplink interfaces.
B. In the LAN cloud on Cisco UCS Manager, enable jumbo frames in Fabric A and Fabric B.
C. In the LAN cloud on Cisco UCS Manager, configure MTU 9000 in the VLAN.
D. In the LAN cloud on Cisco UCS Manager, define a QoS system class with MTU 9000.
E. In the service profile, configure MTU 9000 in the vNIC.
F. In the service profile, configure MTU 9000 in the virtual machine.
G. In the service profile, configure MTU 9000 in the uplink interfaces.
Correct Answer: DE

QUESTION 3
Which three items represent some of the components to implement Cisco VM-FEX for Cisco Unified Computing System Manager B-Series blades? (Choose three.)
A. Cisco VSM VM
B. VEM installed on the VMware vCenter server
C. VEM in the VMware ESX or ESXi host
D. Cisco Unified Computing System Manager version 1.2 or higher
E. VMware vCenter server
F. Fibre Channel VMFS volume
Correct Answer: CDE

QUESTION 4
Which three items represent some of the features that can be defined in a Cisco Unified Computing System Manager port profile? (Choose three.)
A. QoS policy
B. ACL
C. NetFlow
D. port security
E. network control policy
F. VLAN or VLANs
Correct Answer: AEF

QUESTION 5
Which three items must be configured in the Port Profile Client in Cisco Unified Computing System Manager? 642-999 dumps (Choose three.)
A. port profile
B. DVS
C. data center
D. folder
E. VMware vCenter IP address
F. VM port group
Correct Answer: BCD

QUESTION 6
If there are four I/O module links from the Cisco Unified Computing System 5108 Blade Chassis to the Cisco Unified Computing System 6248UP Fabric Interconnect, which dynamic vNICs can be defined?
A. 9
B. 16
C. 24
D. 48
E. 54
F. 112
Correct Answer: E

QUESTION 7
Which two of the listed BIOS options are required for VM-FEX in high performance mode? (Choose two.)
A. RSS
B. interrupt coherency
C. virtualization technology
D. cache validation
E. ATS support
Correct Answer: CE

QUESTION 8
When adding a VMware ESXi host to the Distributed Virtual Switch, what are two risks of migrating a VMNIC that is associated to vSwitch 0? (Choose two.)
A. loss of access to the management IP interface
B. duplicate IP address error
C. duplicate MAC address error
D. loss of VMware ESXi communication with VMware vCenter
E. DVS port group will not appear in the VM network settings
F. DVS port group will overwrite the port groups in vSwitch 0
Correct Answer: AD

QUESTION 9
Which VMware ESXi 5.0 CLI command will validate PassThru interfaces when they are available?
A. vem status -v
B. vempassthru-v
C. vemintf -v
D. vemifconfig -v
E. vempts -v
Correct Answer: A

QUESTION 10
Which three items are supported operating systems of the Cisco VM-FEX universal passthrough? (Choose three.)
A. Oracle Solaris 11
B. Red Hat Enterprise Linux 6.0
C. Microsoft Windows Server 2003 SP3
D. Microsoft Windows Server 2008
E. Ubuntu Server 12.2
F. SLES 11
Correct Answer: BDF

QUESTION 11
Which item is required for communication between Cisco Unified Computing System Manager and VMware vCenter? 642-999 dumps
A. VeriSign Digital Certificates
B. RSA Digital Certificates
C. Cisco Unified Computing System Manager Extension Key
D. VeriSign Plug-In
E. WMware vCenter Certificate Services
Correct Answer: C

QUESTION 12
How many certificates does Cisco Unified Computing System Manager have to export to communicate with VMware vCenter server if the VMware ESXi hosts are all running version 5.0 or higher?
A. 1
B. 2
C. 4
D. 8
E. 16
Correct Answer: A

QUESTION 13
What is the purpose of the maximum ports that are filed in the port profile?
A. determines the maximum number of uplinks that VMs can use
B. determines the maximum number of VMs that can use the DVS
C. determines the maximum number of DVSs that can use the port profile
D. determines the maximum number of dynamic vNICS on the DVS
Correct Answer: D

QUESTION 14
What is the maximum number of ports on a VMware vCenter Distributed Virtual Switch?
A. 64
B. 128
C. 1024
D. 4096
E. 8192
Correct Answer: D

QUESTION 15
In the Create Dynamic vNIC Connection Policy dialog box, there is a configurable field titled Protection. What is the significance of the three choices for Protection?
A. allows reserve vNICs to be allocated out of the spares pool
B. enables hardware-based failover
C. enables static binding of the VM port profile to dynamic vNICs
D. selects the primary fabric association for dynamic vNICs
E. allows dynamic vNICs to be reserved for fabric failover
Correct Answer: D

QUESTION 16
How does a dynamic vNIC get allocated?
A. Dynamic vNICs are assigned to VMs in VMware vCenter.
B. Dynamic vNICs can only be bound to the service profile through an updating template.
C. Dynamic vNICs are bound directly to a service profile.
D. Dynamic vNICs are assigned by binding a port profile to the service profile.
Correct Answer: C

QUESTION 17
After staging a VEM file on a VMware ESXi 5.0 host in the /tmp directory, what is the correct command syntax to install the VEM? 642-999 dumps
A. esxcli software vib install d /tmp/VEM500-20110825132140-BG-release.zip -maintenance-mode
B. esxcli software vib install v /tmp/VEM500-20110825132140-BG-release.zip -maintenance-mode
C. esxupdate software vib install d /tmp/VEM500-20110825132140-BG-release.zip -maintenance-mode
D. esxupdate software vib install v /tmp/VEM500-20110825132140-BG-release.vib -maintenance-mode
Correct Answer: A

QUESTION 18
Which network driver is required on a VMware ESXi 5.0 host for a vNIC to enter Cisco VM-FEX universal passthrough mode?
A. VMXNET3
B. Vlance
C. Flexible
D. E1000e
E. VMXNET5
Correct Answer: A

QUESTION 19
Which virtual hardware version is required for a VM to enter the Cisco VM-FEX universal passthrough mode?
A. Version 5
B. Version 6
C. Version 7
D. Version 8
E. Version 9
Correct Answer: D

QUESTION 20
Which feature must be configured for Linux VMs to be able to transition from Cisco VM-FEX standard mode to universal passthrough mode?
A. RSS
B. MSI Interrupt Mode
C. VEMDPA Agent
D. Execute Disabled Bit
E. Processor C State
Correct Answer: B

QUESTION 21
Which of the following is true concerning the Global Chassis Discovery policy configuration on the Cisco Unified Computing System Manager when using Cisco Unified Computing System 22XX I/O modules with Cisco UCS 62XX Fabric Interconnects?
A. The link grouping preference should be set to discrete mode when the number of northbound links are not a power of 2.
B. Set the action policy-count higher than the actual number of uplinks; otherwise, the Cisco Unified Computing System servers will not be discovered.
C. For Cisco Unified Computing System implementations that mix I/O modules with different numbers of links, it is best to manually reacknowledge the chassis in order to use all available links.
D. Automatic reacknowledgement due to chassis discovery is never disruptive.
Correct Answer: C

QUESTION 22
Which of the following is the most accurate concerning the link configuration between Cisco Unified Computing System 22XX I/O modules and Cisco Unified Computing System 62XX Fabric Interconnects? 642-999 dumps
A. Port channels are always recommended when using source-dest-mac load balancing.
B. The addition of links to a port channel requires a reacknowledgement.
C. You cannot mix and match discrete links and port channeling for different chassis when using 22XX.
D. Port channels do not require a Global Chassis Discovery policy.
Correct Answer: A

QUESTION 23
Which of the following is not a feature of the Cisco Unified Computing System VIC-1280 adaptor?
A. capable of up to 256 virtual interfaces
B. supports FCoE
C. supports Cisco VM-FEX
D. compatible with the C- or B-Series Cisco Unified Computing System servers
Correct Answer: D

QUESTION 24
Which of the following is true with respect to recovery from failure with automatic pinning that is configured on a cluster of Cisco Unified Computing System 62XX Fabric Interconnects?
A. By default, server MAC addresses are pinned to uplink interfaces using PIN groups.
B. When a northbound fabric interconnect link goes down, the affected servers will use NIC teaming to re-establish connectivity on the second fabric interconnect.
C. When a northbound fabric interconnect link goes down, the fabric interconnect will send a gratuitous ARP to the northbound switch to announce the servers on the new port.
D. In the event that all uplink ports on the fabric interconnect lose connectivity, the 22XX I/O module shuts down all of the host ports until at least one uplink is restored.
Correct Answer: C

QUESTION 25
How does a Cisco Unified Computing System react when configured for disjoint Layer 2 domains?
A. Automatic pinning is disabled; VLAN membership must be statically pinned to the uplink ports.
B. VLANs must be divided between the fabric interconnects using PIN groups.
C. The VLAN traffic for a disjoint network can only travel along an uplink that is specifically assigned to this VLAN and is selectively excluded from all other uplinks.
D. When you configure disjoint Layer 2 networks, you must assign VLANs to uplink interfaces.
Correct Answer: C

High qiality Cisco CCNP Data Center 642-999 dumps exam practice materials in PDF format free download from lead4pass. The best and most updated latest Cisco CCNP Data Center https://www.lead4pass.com/642-999.html dumps pdf training resources which are the best for clearing 642-999 exam test, and to get certified by Cisco CCNP Data Center, 100% pass guarantee.

Best Cisco CCNP Data Center 642-999 dumps vce youtube: https://youtu.be/dB9zJyqEvmM